Cooling technique for divertor with metal porous media
Page 1 : Cooling technique for divertor
with metal porous media
Page 2 : Other applications of cooling technique with metal porous media
Page 3 : Publised Papers
Cooling technique for divertor with metal porous media
We proposed cooling technique using sintered metal porous media.
This cooling technique is based on heat removal by latent heat of vaporization of coolant
flowing in the porous media.
One side of the porous media is touched to high heat load surface, and the other side is
soaked in coolant.
Coolant penetrates into the porous media and evaporates due to transmitted heat.
Advantages of the cooling system are as follows.
- Thermal energy is transmitted into the inside of coolant
because large thermal conductivity of metal material.
- Coolant is given to the high heat load surface continuously
because of sintered metal porous media's capillary force.
That prevent the coolant from transforming to the film boiling state.
- High temperature steam is available because of making
coolant evaporate positively.
|
|
sintered porous media (Copper fiber) |
|
|
Experimental set-up |
Temperature distribution in porous media and heat sink material |
http://web.tohoku.ac.jp/hashizume_fan_club/
hashizume-stafflovehashizume@grp.tohoku.ac.jp
Copyright © Hashizume & Ito & Ebara & Cheng Lab., All Rights Reserved.